Differential controller SGC16H

Differential controller SGC16H

0%

    Presentation

    The differential controller SGC16H is intended for the control of domestic hot water heating systems with flat or vacuum collectors.

    • In domestic hot water heating systems with flat or vacuum collectors.
    • In domestic hot water heating systems with auxiliary heat sources.

    Features

    • 5 preset hydraulic schemes.
    • Rotation speed control of 1 classical pump (RMP).
    • Rotation speed control of 1 energy-efficient pump (PWM, 0–10 V).
    • System regulation with 1 collector field.
    • System regulation with 1 heat storage tank.
    • Possibility to control heating systems using a solid fuel boiler.
    • Wizard for an easy and quick device start-up.
    • Measurement and display of generated energy.
    • Solar system protection when collectors are overheating.
    • Notifications on the activated protection functions and warnings about system failures.
    • Possibility to simulate sensors and analyse the system operation.
    • Remote control with the help of the SeltronHome system.

    Outlined functions

    Start-up wizard

    The SGC controller is equipped with a start-up wizard, which takes you through the initial setup of the controller in 2 steps.

    Step 1: language selection.
    Step 2: hydraulic scheme selection.

    Measurement of the energy obtained

    When the solar system is also used for domestic hot water heating, we want to know how much heating energy has been obtained from the solar system. The SGC controllers provide an informative and accurate measurement of the solar energy obtained and the display of the data in weekly, monthly and yearly diagrams.
    • For informative measurements of the solar energy obtained, the maximum reading of the medium flow from the mechanical meter must be entered in the controller setup.
    • For accurate measurements of the solar energy obtained, a flow meter with a pulse generator or a Vortex flow meter (VFS) must be installed in the solar system.

    Connection of an energy-saving circulation pump with external controlled signal

    The SGC controller features the speed control of energy-saving circulation pumps with external controlled PWM signal or 0÷10 V. This type of speed control is possible with R2 and R3 relay outputs. All SGC controllers feature the R2 relay output, while the SGC36HV and SGC67HV controllers feature the R3 relay output.

    KXD Remote control with the help of SeltronHome system

    The SGC controllers may be connected to the SeltronHome platform, which provides the heating remote control using a smartphone or tablet. Remote control is enabled through the CLAUSIUS application for the end user and the KELVIN app for service technicians. With the application you can, for example, switch on one-time domestic hot water heating process outside of a time programme.

    Typical hydraulic scheme

    Solar collectors, domestic hot water storage tank, solid fuel boiler, auxiliary heating with electricity.

    Example: hydraulic scheme 231d.

    Technical data

    Technical dataSGC16H
    Backlit graphic display
    Operating hours meter
    Weekly program timer
    Connection voltage230 V~, 50 Hz
    Own consumption 2.5 W
    Standby power consumptionMax. 0.5 W
    No. of inputs6 pcs temperature sensor (Pt 1000)
    1 pc pulse input
    No. of outputs1 pc Triac for speed control (R2)
    1 pc PWM or analogue 0÷10 V
    Relay outputs4 (1) A ~, 230 V~
    Triac outputs1 (1) A ~, 230 V~
    Power supply of built-in clockBattery CR2032 (Li-Mn) 3 V
    Accuracy of built-in clock+/-1 s (24 h) at 20 °C
    Degree of protectionIP20 / EN60529
    Safety classI according to EN 60730-1
    Operation mode1B according to EN 60730-1
    Type of temperature sensorsPt1000 or KTY10
    Housing materialASA – thermoplastic
    Permissible ambient temperature 0÷40 °C
    Storage temperature-20÷65 °C
    Product weight400 g
    Number of pieces in a package unit6 pieces
    DimensionsSGC mere
    Electrical connectionSGC16H elektro priključitev

    Performance comparison

    SGC16HSGC26HSGC36HVSGC67HV
    Application
    In domestic hot water heating systems with flat or vacuum collectors
    In domestic hot water heating systems with auxiliary heat sources
    In storage tank heating systems using a solar system and auxiliary heat sources
    In pool heating systems
    For a single-stage storage tank loading
    For a two-stage storage tank loading
    Technical characteristics
    No. of preset hydraulic schemes5225365
    No. of mechanical relays114
    Number of electronic relays1122
    No. of temperature sensor inputs6667
    Number of collector fields1222
    No. of storage tanks1233
    Measurement of the energy obtained (kWh)
    Option for pulse meter flow measurement (l/min)
    Possibility for flow measurement with a Vortex sensor VFS
    Speed control for energy-saving pumps (PWM, 0÷10 V)1 pump1 pump2 pumps2 pumps
    Speed control for standard pumps (RPM)1 pump1 pump2 pumps2 pumps
    Free programming option1 output2 outputs3 outputs
    System control
    Collector fields1222
    Storage tanks1up to 2up to 3up to 3
    Solar system domestic hot water heating and an auxiliary heat source
    Heating support
    Pool heating
    Using a solid fuel boiler
    Quick cold storage tank start function
    Heat source control
    Flat or vacuum collectors
    Solid fuel boiler
    Solid fuel boiler with a pellet burner
    Liquid fuel boiler
    Combined boiler
    Gas flow boiler
    Heat pump
    Storage tank
    Auxiliary heating using electric heater
    Options for switching on auxiliary energy sources
    The controller features the option of an auxiliary source for heating the water to the minimum temperature
    The option for starting the primary energy source immediately or only when the water cannot be heated in a certain period of time
    The option for configuring the time during which we allow water heating only by using collectors – the controller will not switch on the primary heat source if the calculations show that the water can be heated only by collectors
    Operation mode with several storage tanks
    Constant operation in the “OPTIMUM” mode means an optimum use of solar energy for heating all of the storage tanks taking into account the preferred storage tank
    The "AUTO" operation mode automatically switches between winter and summer modes according to a preset calendar
    Constant operation in the “SUMMER” mode means the heating of only the preferred storage tank, other storage tanks are heated only when the preferred one reaches the desired temperature
    Continuous operation in the “WINTER” mode means an alternating parallel heating of all storage tanks
    Heating of all storage tanks
    User functions
    Domestic hot water heating according to the time programme
    Holiday operation mode
    One-time domestic hot water heating
    Heating system protection
    Anti-legionella protection (for a controlled energy source)
    Collector frost protection
    Forced pump start at the highest collector temperature
    Switching off of the pump when the safety temperature has been exceeded
    Solar system protection when collectors are overheating
    Storage tank overheating protection
    Storage tank recooling to the desired temperature
    Periodic starts of pumps during a period of inactivity
    A comprehensive overview of the heating system operation
    Graphic display of temperatures according to days of the last week
    Detailed display of temperatures for the current day
    Archiving and graphic display of the solar energy obtained
    Notifications on the activated protection functions and warnings about system failures
    Possibility to simulate sensors and analyse the system operation.
    Remote access
    Possibility of USB connection to a PC
    Possibility of connectivity to the SeltronHome platform, which allows remote control via a smartphone or tablet
    Setup and installation
    Wizard for an easy and quick device start-up
    13-language user interface
    Languages: EN, DE, FR, NL, PL, ES, SL, IT, CS, LT, GR, HU, HR
    Setting up the operation by selecting the hydraulic scheme
    “Help” button for quick help with the setup
    Graphically adjustable time programmes
    Option to simulate the system operation
    Logging and display of changes made to the setup
    Option for retrieval of the basic setup in the event of data loss or unwanted changes
    Option for programming free outputs
    Possibility of wall or DIN rail installation
    Simple installation and connection

    NOTICE

    Dear customers!

    Please be informed that our store Seltron d.o.o. will be closed on the following days 12-13 January 2024 for annual inventory purposes.

    Thank you for your understanding.

    NOTICE

    The Seltron service will be closed from 27 December to 29 December 2023.

    Any emergencies or issues that arise during our absence will be dealt with as soon as the service reopens on 3 January 2024.

    Thank you for your understanding.