Differential controller SGC26H
0%
Presentation
The differential controller SGC26H is intended for the control of domestic hot water heating systems with flat or vacuum collectors and auxiliary heat sources.
- In domestic hot water heating systems with flat or vacuum collectors.
- In domestic hot water heating systems with auxiliary heat sources.
- In storage tank heating systems using a solar system and auxiliary heat sources.
- In pool heating systems.
Features
- 22 preset hydraulic schemes.
- 1 freely programmable output.
- Rotation speed control of 1 classical pump (RMP).
- Rotation speed control of 1 energy-efficient pump (PWM, 0–10 V).
- Control of two collector field systems.
- Control of 2 storage tanks systems.
- Possibility to control heating systems using a solid fuel boiler.
- Wizard for an easy and quick device start-up.
- Measurement and display of generated energy.
- Solar system protection when collectors are overheating.
- Notifications on the activated protection functions and warnings about system failures.
- Possibility to simulate sensors and analyse the system operation.
- Remote control with the help of the SeltronHome system.
Documentation
Download
Outlined functions
Start-up wizard
Measurement of the energy obtained
When the solar system is also used for domestic hot water heating, we want to know how much heating energy has been obtained from the solar system.
The SGC controllers provide an informative and accurate measurement of the solar energy obtained and the display of the data in weekly, monthly and
yearly diagrams.
- For informative measurements of the solar energy obtained, the maximum reading of the medium flow from the mechanical meter must be entered in the controller setup.
- For accurate measurements of the solar energy obtained, a flow meter with a pulse generator or a Vortex flow meter (VFS) must be installed in the solar system.
Connection of an energy-saving circulation pump with external controlled signal
The SGC controller features the speed control of energy-saving circulation pumps with external controlled PWM signal or 0÷10 V. This type of speed
control is possible with R2 and R3 relay outputs. All SGC controllers feature the R2 relay output, while the SGC36HV and SGC67HV controllers feature the R3
relay output.
KXD Remote control with the help of SeltronHome system
The SGC controllers may be connected to the SeltronHome platform, which provides the heating remote control using a smartphone or tablet.
Remote control is enabled through the CLAUSIUS application for the end user and the KELVIN app for service technicians.
With the application you can, for example, switch on one-time domestic hot water heating process outside of a time programme.
Typical hydraulic scheme
Technical data
Tehnični podatki | SGC26H |
---|---|
Backlit graphic display | |
Operating hours meter | |
Weekly program timer | |
Connection voltage | 230 V~, 50 Hz |
Own consumption | 2.5 W |
Standby power consumption | Max. 0.5 W |
No. of inputs | 6 pcs temperature sensor (Pt 1000) 1 pc pulse input |
No. of outputs | 1 pc Triac for speed control (R2) 1 pc PWM or analogue 0÷10 V (Y2) |
Relay outputs | 4 (1) A ~, 230 V~ |
Triac outputs | 1 (1) A ~, 230 V~ |
Power supply of built-in clock | Battery CR2032 (Li-Mn) 3 V |
Accuracy of built-in clock | +/-1 s (24 h) at 20 °C |
Degree of protection | IP20 / EN60529 |
Safety class | I according to EN 60730-1 |
Operation mode | 1B according to EN 60730-1 |
Type of temperature sensors | Pt1000 or KTY10 |
Housing material | ASA – thermoplastic |
Permissible ambient temperature | 0÷40 °C |
Storage temperature | -20÷65 °C |
Product weight | 400 g |
Number of pieces in a package unit | 6 pieces |
Dimensions | |
Electrical connection |
Performance comparison
SGC16H | SGC26H | SGC36HV | SGC67HV | |
---|---|---|---|---|
Application | ||||
In domestic hot water heating systems with flat or vacuum collectors | ||||
In domestic hot water heating systems with auxiliary heat sources | ||||
In storage tank heating systems using a solar system and auxiliary heat sources | — | |||
In pool heating systems | — | |||
For a single-stage storage tank loading | — | — | ||
For a two-stage storage tank loading | — | — | — | |
Technical characteristics | ||||
No. of preset hydraulic schemes | 5 | 22 | 53 | 65 |
No. of mechanical relays | — | 1 | 1 | 4 |
Number of electronic relays | 1 | 1 | 2 | 2 |
No. of temperature sensor inputs | 6 | 6 | 6 | 7 |
Number of collector fields | 1 | 2 | 2 | 2 |
No. of storage tanks | 1 | 2 | 3 | 3 |
Measurement of the energy obtained (kWh) | ||||
Option for pulse meter flow measurement (l/min) | ||||
Possibility for flow measurement with a Vortex sensor VFS | — | — | ||
Speed control for energy-saving pumps (PWM, 0÷10 V) | 1 pump | 1 pump | 2 pumps | 2 pumps |
Speed control for standard pumps (RPM) | 1 pump | 1 pump | 2 pumps | 2 pumps |
Free programming option | — | 1 output | 2 outputs | 3 outputs |
System control | ||||
Collector fields | 1 | 2 | 2 | 2 |
Storage tanks | 1 | up to 2 | up to 3 | up to 3 |
Solar system domestic hot water heating and an auxiliary heat source | — | |||
Heating support | — | |||
Pool heating | — | |||
Using a solid fuel boiler | — | — | — | |
Quick cold storage tank start function | — | — | — | |
Heat source control | ||||
Flat or vacuum collectors | ||||
Solid fuel boiler | ||||
Solid fuel boiler with a pellet burner | — | |||
Liquid fuel boiler | — | |||
Combined boiler | — | |||
Gas flow boiler | — | |||
Heat pump | — | |||
Storage tank | ||||
Auxiliary heating using electric heater | — | |||
Options for switching on auxiliary energy sources | ||||
The controller features the option of an auxiliary source for heating the water to the minimum temperature | ||||
The option for starting the primary energy source immediately or only when the water cannot be heated in a certain period of time | — | |||
The option for configuring the time during which we allow water heating only by using collectors – the controller will not switch on the primary heat source if the calculations show that the water can be heated only by collectors | — | |||
Operation mode with several storage tanks | ||||
Constant operation in the “OPTIMUM” mode means an optimum use of solar energy for heating all of the storage tanks taking into account the preferred storage tank | — | |||
The "AUTO" operation mode automatically switches between winter and summer modes according to a preset calendar | — | |||
Constant operation in the “SUMMER” mode means the heating of only the preferred storage tank, other storage tanks are heated only when the preferred one reaches the desired temperature | — | |||
Continuous operation in the “WINTER” mode means an alternating parallel heating of all storage tanks | — | |||
Heating of all storage tanks | — | |||
User functions | ||||
Domestic hot water heating according to the time programme | ||||
Holiday operation mode | ||||
One-time domestic hot water heating | ||||
Heating system protection | ||||
Anti-legionella protection (for a controlled energy source) | ||||
Collector frost protection | ||||
Forced pump start at the highest collector temperature | ||||
Switching off of the pump when the safety temperature has been exceeded | ||||
Solar system protection when collectors are overheating | ||||
Storage tank overheating protection | ||||
Storage tank recooling to the desired temperature | ||||
Periodic starts of pumps during a period of inactivity | ||||
A comprehensive overview of the heating system operation | ||||
Graphic display of temperatures according to days of the last week | ||||
Detailed display of temperatures for the current day | ||||
Archiving and graphic display of the solar energy obtained | ||||
Notifications on the activated protection functions and warnings about system failures | ||||
Possibility to simulate sensors and analyse the system operation. | ||||
Remote access | ||||
Possibility of USB connection to a PC | ||||
Possibility of connectivity to the SeltronHome platform, which allows remote control via a smartphone or tablet | ||||
Setup and installation | ||||
Wizard for an easy and quick device start-up | ||||
13-language user interface | ||||
Languages: EN, DE, FR, NL, PL, ES, SL, IT, CS, LT, GR, HU, HR | ||||
Setting up the operation by selecting the hydraulic scheme | ||||
“Help” button for quick help with the setup | ||||
Graphically adjustable time programmes | ||||
Option to simulate the system operation | ||||
Logging and display of changes made to the setup | ||||
Option for retrieval of the basic setup in the event of data loss or unwanted changes | ||||
Option for programming free outputs | ||||
Possibility of wall or DIN rail installation | ||||
Simple installation and connection |
Complementary products
-
Communication interface GWD
The GWD3E communication interface is intended for connection of Seltron controllers, room units...
-
Actuators AVD
AVD actuators are intended for position control of rotary mixing and ball valves.
-
Immersion temperature sensor TF/Pt
Potopno temperaturno tipalo TF/Pt se uporablja za merjenje temperature v…
-
Surface temperature sensor VF/Pt
Naležno temperaturno tipalo VF/Pt se uporablja za merjenje temperature v…