Zone heating controller ZCE6 Advance

Zone heating controller ZCE6 Advance

0%

    Presentation

    ZCE6 Advance controllers have been designed for the control of zone heating and/or cooling. It also features the control of the energy source, mixing valve and circulation pump.

    • Floor heating or cooling system control.
    • Wall or ceiling heating or cooling system control.
    • Convector heating or cooling system control.

    Features

    • Up to 3 preset hydraulic schemes.
    • Control of 6 independent temperature zones.
    • Possibility of selecting supply voltage for thermal actuators: for 24 V~ or 230 V~.
    • By connecting an antenna, also wireless room units can be connected to the controller, among others as a combination of a wired and wireless room unit.
    • Completely quiet control of thermal actuators with solid state relays.
    • Circulation pump control.
    • Energy source control.
    • Supply temperature control with mixing valve.
    • Possibility of joining temperature zones into one homogeneous zone.
    • Option of a BUS connection of multiple controllers.

    Outlined functions

    Thermal actuator control with a voltage of 24 V~ or 230 V~

    The controller provides the connection of thermal actuators with a supply voltage of 230 V~ or 24 V~. The controller is pre-configured for 230 V~ power supply. In order to change the supply voltage to 24 V~, the protective cover must be removed, the switch must be moved into the 24 V~ position and the 24 V~ terminal must be connected to the ZCEPS power supply.

    Simple procedure for connecting the heating zones with room units

    Each room unit represents one temperature zone and can affect one or more heating zones. Establishing a connection between the controller and the room units as well as determining the effect of the room unit on the zones is carried out by a pairing process.

    The pairing process is carried out in two simple steps.
    • First, the controller activates the room unit pairing function. The controller waits for the first zone to be paired with the appurtenant room unit. We can also select the zone to be paired manually.
    • Secondly, the pairing is executed by pressing the - and + keys on the relevant room unit. The room unit is automatically paired with the selected zone on the controller. After a successful pairing process, the controller automatically activates the pairing of the next vacant zone. The process is repeated until all room units have been paired.

    Possibility of selection of room units

    The ZCE zone controller provides the connection of wired and wireless room units, or the combination of both.

    RCD40 room unit features
    • Measurement and setting of the room temperature.
    • Time programme configuration.
    • Operation mode setting.
    • PARTY, ECO, HOLIDAY and FIREPLACE user functions.
    • Display of information on the controller operation.
    • Wired (BUS) or wireless connection.

    WDC BUS connection of multiple controllers

    When controlling demanding heating systems, several ZCE controllers can be interconnected into a comprehensive heating system. One controller must be set as the leading or “master” controller. Through the BUS connection, the master controller sends information on measured temperatures and the operation mode to all the slave controllers. The master controller receives requests to activate a source from slave controllers.

    Software update

    The controller and room unit software may be updated through the USB connection using a smart device.

    Technical data

    Tehnični podatkiZCE6 Advance
    Weekly program timer
    Connection voltage230 V~, 50 Hz
    Own consumption5 W
    Standby power consumptionMax. 0.5 W
    No. of inputs3 pcs temperature sensor (Pt 1000)
    3 digital inputs
    No. of outputs6 pcs solid state relay for zone control
    2 pcs relay output for controlling the energy source and circulation pump
    2 pcs solid state relay for mixing valve control
    Relay outputs4 (1) A ~, 230 V~
    Triac outputs1 (1) A ~, 230 V~
    Power supply of built-in clockBattery R1025 (Li-Mn) 3 V
    Accuracy of built-in clock+/-1 s (24 h) at 20 °C
    Degree of protectionIP20 according to EN 60529
    Safety classI according to EN 60730-1
    Operation mode1B according to EN 60730-1
    Type of temperature sensorsPt1000
    Operation modePI controller
    Housing materialPC+ABS – thermoplastic
    Permissible ambient temperature5÷40 °C
    Storage temperature-20÷65 °C
    Product weight370 g
    Number of pieces in a package unit6 pieces
    DimensionsZCE dimensions
    Electrical connectionZCE electrical connection

    Performance comparison

    ZCE6 BasicZCE6 Advance
    Application
    Floor heating or cooling system control
    Wall or ceiling heating or cooling system control
    Convector heating or cooling system control
    Technical characteristics
    Control of 6 independent temperature zones
    Possibility of selecting supply voltage for thermal actuators: for 24 V~ or 230 V~
    By connecting an antenna wired or wireless room units or a combination of both can be connected to the controller
    Completely quiet control of thermal actuators with solid state relays
    Max. no. of room units66
    Circulation pump control
    Supply temperature control with mixing valve
    Possibility of joining temperature zones into one homogeneous zone.
    Possibility of energy source control
    No. of temperature sensor inputs33
    No. of digital inputs33
    No. of analogue outputs11
    No. of outputs (zones/other outputs)6/06/4
    Max. number of controllers in a BUS connection66
    System control
    Floor heating or cooling system control
    Wall or ceiling heating or cooling system control
    Convector heating or cooling system control
    Heating circuits control
    Control of the supply line constant temperature
    Weather-compensated supply line temperature control
    Energy source control
    Source on/off
    User functions
    Room heating or cooling according to the time programme
    Automatic winter/summer mode switchover
    PARTY function – activation of the comfort operation mode
    ECO function – activation of the economy operation mode
    HOLIDAY function – activation of the operation mode during the holiday season
    Emergency operation when communication with the room unit is lost
    Heating system protection
    Room frost protection
    Room overheating protection
    Periodic start of thermal actuators during a period of inactivity
    Periodic start of the pump and mixing valve during a period of inactivity
    Data display
    LED zone operation indicator
    LED indicator of circulation pump operation
    LED indicator of energy source operation
    LED indicator of mixing valve operation
    LED indicator of BUS connection
    Remote access
    Possibility of USB connection to a PC
    Setup and installation
    Installation onto the installation rail
    Simple installation and connection

    NOTICE

    Dear customers!

    Please be informed that our store Seltron d.o.o. will be closed on the following days 12-13 January 2024 for annual inventory purposes.

    Thank you for your understanding.

    NOTICE

    The Seltron service will be closed from 27 December to 29 December 2023.

    Any emergencies or issues that arise during our absence will be dealt with as soon as the service reopens on 3 January 2024.

    Thank you for your understanding.