    WDC10B weather compensated controllers are intended for the control of room heating and domestic hot water heating in single-family houses.

    • Radiator room heating system control.
    • Floor heating or cooling system control.
    • Convector heating or cooling system control.
    • Wall or ceiling heating or cooling system control.
    • Domestic hot water heating.

    Features

    • 7 preset hydraulic schemes.
    • They may be used for the control of new systems or to replace the installed controllers.
    • Room heating or cooling according to the time programme.
    • Domestic hot water heating according to the time programme.
    • Control of heating systems with a storage tank.
    • The possibility of connecting 2 room units.
    • BOOST function for intense room heating.
    • 13-language user interface.
    • Wizard for an easy and quick device start-up.
    • Possibility to simulate sensors and analyse the system operation.
    • Remote control with the help of the SeltronHome system.

    Outlined functions

    Start-up wizard

    The WDD controller is equipped with a start-up wizard, which takes you through the initial setup of the controller in 3 or 4 steps.

    Step 1: language selection.
    Step 2: hydraulic scheme selection.
    Step 3: setting the heating curve for the first heating circuit.
    Step 4: setting the heating curve for the second heating circuit.

    WDC Possibility to connect a Seltron room unit

    The WDC controller provides the connection of RCD room units. The room unit provides measurements of room temperature, selection of operation mode and setting of daytime and nighttime temperatures. Up to two room units may be connected to one WCD controller.

    WDC BUS connection of multiple controllers

    A random number of WDC controllers can be interconnected with the BUS connection. The master controller controls heat sources and heating circuits, meanwhile the slave controllers only control heating circuits. The outdoor sensor and the boiler temperature sensor are connected to the master controller.

    WXD Remote control with the help of SeltronHome system

    The WDC controllers may be connected to the SeltronHome platform, which provides the heating remote control using a smartphone or tablet. Remote control is enabled through the CLAUSIUS application for the end user and the KELVIN app for service technicians. The CLAUSIUS application provides the adaptation of the heating to our lifestyle, which leads to greater comfort and reduced heating expenses.

    Typical hydraulic scheme

    Oil boiler, 2 mixing circuits, domestic hot water storage tank.

    Example: hydraulic scheme 423.

    Technical data

    Tehnični podatkiWDC10B
    Backlit graphic display
    Operating hours meter
    Weekly program timer
    Connection voltage230 V~, 50 Hz
    Own consumption 2.5 W
    Standby power consumptionMax. 0.5 W
    No. of inputs7 pcs temperature sensor (Pt 1000)
    No. of outputs6 pcs mechanical
    2 pcs PWM or analogue 0÷10 V (Y2)
    Relay outputs4 (1) A ~, 230 V~
    Triac outputs1 (1) A ~, 230 V~
    Power supply of built-in clockBattery CR2032 (Li-Mn) 3 V
    Accuracy of built-in clock+/-1 s (24 h) at 20 °C
    Degree of protectionIP20 according to EN 60529
    Safety classI according to EN 60730-1
    Operation mode1B according to EN 60730-1
    Type of temperature sensorsPt1000 or KTY10
    Operation mode3-point PID
    Housing materialASA – thermoplastic
    Permissible ambient temperature5÷40 °C
    Storage temperature-20÷65 °C
    Product weight410 g
    Number of pieces in a package unit6 pieces
    DimensionsWDC dimensions
    Electrical connectionWDC electrical connection

    Performance comparison

    WDC10BWDC10WDC20
    Application
    Radiator room heating system control
    Floor heating or cooling system control
    Convector heating or cooling system control
    Wall or ceiling heating or cooling system control
    Domestic hot water heating
    Technical characteristics
    No. of preset hydraulic schemes71752
    No. of room units222
    No. of mechanical relays667
    Number of electronic relays11
    No. of analogue outputs (0÷10 V or PWM) for the control of the circulation pump or an energy source222
    No. of temperature sensor inputs777
    BUS option – the interconnection of WDC controllers and connection with other Seltron controllers
    System control
    Control of a heating system with radiators
    Floor heating or cooling system control
    Convector heating or cooling system control
    Wall or ceiling heating or cooling system control
    Domestic hot water heating system control
    Heating circuits control
    Direct circuit
    Mixing circuit
    Direct and mixing circuit
    Two mixing circuits
    Domestic hot water heating
    Switchover between direct heating circuit and domestic hot water heating
    Domestic hot water circulation
    Automatic switchover between heat sources
    Control of the supply line constant temperature
    Single-stage storage tank loading
    Heat source control
    Solid fuel boiler
    Solid fuel boiler with a pellet burner
    Liquid fuel boiler
    Liquid fuel boiler with a two-stage burner
    Combined boiler
    Gas flow boiler
    Heat pump
    Storage tank
    Auxiliary heating with electricity
    Solar collectors
    Domestic hot water heating
    With a primary heating source
    With a storage tank
    Using a solar system
    User functions
    Room heating or cooling according to the time programme
    Automatic winter/summer mode switchover
    PARTY function – activation of the comfort operation mode
    ECO function – activation of the economy operation mode
    HOLIDAY function – activation of the operation mode during the holiday season
    Domestic hot water heating according to the time programme
    One-time domestic hot water heating
    BOOST function for intense room heating
    Function for screed drying
    Heating system protection
    Anti-legionella protection (for a controlled energy source)
    Storage tank overheating protection
    Boiler overheating protection
    Collector frost protection
    Forced pump start at the highest collector temperature
    Switching off of the pump when the safety temperature has been exceeded
    Solar system protection when collectors are overheating
    Storage tank recooling to the desired temperature
    Periodic start of the pump and mixing valve during a period of inactivity
    A comprehensive overview of the heating system operation
    Graphic display of temperatures according to days of the last week
    Detailed display of temperatures for the current day
    Notifications on the activated protection functions and warnings about system failures
    Possibility to simulate sensors and analyse the system operation.
    Remote access
    With a separate dedicated cable, the controller can be connected to a computer
    Possibility of connectivity to the SeltronHome platform, which allows remote control via a smartphone or tablet
    Setup and installation
    Wizard for an easy and quick device start-up
    13-language user interface
    Languages: EN, DE, FR, NL, PL, ES, SL, IT, CS, LT, GR, HU, HR
    Setting up the operation by selecting the hydraulic scheme
    “Help” button for quick help with the setup
    Graphically adjustable time programmes
    Option to simulate the system operation
    Logging and display of changes made to the setup
    Option for retrieval of the basic setup in the event of data loss or unwanted changes
    Option for programming free outputs
    Possibility of wall or DIN rail installation
    Simple installation and connection

    NOTICE

    Dear customers!

    Please be informed that our store Seltron d.o.o. will be closed on the following days 12-13 January 2024 for annual inventory purposes.

    Thank you for your understanding.

    NOTICE

    The Seltron service will be closed from 27 December to 29 December 2023.

    Any emergencies or issues that arise during our absence will be dealt with as soon as the service reopens on 3 January 2024.

    Thank you for your understanding.